Page 42 - Broken Arrow, OK Residential District Design Guidelines
P. 42

SINGLE-FAMILY







         BUILDING FORM

          A A  Front Wall Width

              Area 1 & 5    45’ Max. 1
              Area 2        50’ Max. 2
              Area 3        50’ Max. 3
              Area 4        45’ Min., 80’ Max.
          B B  Building Height

              Area 1, 2, 3, 4 & 5  2.5 stories/35’ Max. 4
          C   Finished Floor Height


              Area 1, 2, 3, 4 & 5  1’ Min.; 4’Max.
          D   Floor Height

              Area 1, 2, 3, 4 & 5  9’ Min.
          D E  Roof Form

              Area 1 & 5    Pitched or flat
              Area 2, 3 & 4  Pitched
          D F  Garage and Carport Width
                            25’ or 40% width of primary structure:
              Area 1, 2, 3, 4 & 5
                            max. street-facing garage door width 5
          G   Garage Door/Carport Height

              Area 1, 2, 3, 4 & 5  9’ Max. garage door/carport height
          H   Garage and Carport (If Visible)
          D
                            If any portion of the garage is located
                            forward of the rear wall of primary
                            structure:
                            -  Roof of garage or carport must match
              Area 1, 2, 3, 4 & 5
                               roof of primary structure
                            -  Height of garage or carport must be
                                equal to or less than the height of
                                primary structure
          I D  ADU Building Height

              Area 1, 2, 3, 4 & 5  1 story/15’ Max.
          D J  ADU Roof Form

              Area 1, 2, 3, 4 & 5  Must match primary structure
              Additional Information
              1  Only 30’ of total front wall width can be located within 25’ of
               the front lot line. The maximum width is a continuous wall.   4  If a half story is above floor 2, the half story must be contained within the roof
               Building activation requirements apply.
                                                          5  Exception for existing lots 30’ wide or less
              2  Only 40’ of total front wall width can be located within 30’ of
               front lot line.
              3  Only 40’ of total front wall width can be located within 25’ of
               front lot line



        38   Broken Arrow Downtown Residential Overlay District (DROD) Design Standards
   37   38   39   40   41   42   43   44   45   46   47