Page 59 - Broken Arrow, OK Residential District Design Guidelines
P. 59
BUILDING ACTIVATION
A First Story Element
A
Area 1, 5 & 6 Required 1&2
B Principal Windows
Area 1, 5 & 6 1 Min. on front-most wall; 4’x4’ Min.
C Blank Street-Facing Wall
Area 1, 5 & 6 8’ Max.
D Window Size - Street-Facing Wall
F
Area 1, 5 & 6 2’x3’, except for an accent windows 3
E Entries Per Unit
Area 1, 5 & 6 1 Min.
F B Distance Between Entries
Area 1, 5 & 6 30’ Max.
G Entry Location (On Street-Facing Wall)
C
Area 1, 5 & 6 5’ Max. from front-most wall
H Entry Presence - Facing Street
C
Area 1, 5 & 6 Required 4
I Entry Path
Area 1, 5 & 6 Required 5
Additional Information
1 Must include one of the following elements on the front- 3 If height of front wall is greater than 35’, 2 principal windows are required.
most façade of each unit:
• Projecting Porch 4 Visually connect entrance to street through one of the following:
• Recessed Porch • Entry faces street
• Entry opens on porch or stoop that faces street
• Projecting Stoop
2 Height of first story element must have an interior clearance 5 Must connect to street through physical, demarcated path
of at least 8 feet, no greater than 12 feet. Interior clearance
is measured from the floor of the first story element to the
lowest point of the ceiling of the first story element.
Broken Arrow Downtown Residential Overlay District (DROD) Design Standards 55